These AWI-tested engineered drawings indicate the construction methods that have been tested and proven to meet the indicated Performance Duty Level by the AWI National Testing Center in Americus, GA. The use of these drawings alone will not indicate compliance with AWI Standards. In order to achieve compliance with AWI standards, the manufacturer will need to acquire an Official AWI Testing Report and pass an audit inspection verifying the construction methods contained with the Testing Report have been followed.
Base Cabinets
Duty Level 4: Particleboard, MDF, Veneer Core
Wall Cabinets
Duty Level 4: Particleboard, MDF, Veneer Core
Tall Cabinets
Duty Level 3: Veneer Core
- Confirmat (NEW)
Duty Level 4: Particleboard
Duty Level 4: MDF
- Confirmat (NEW)
Duty Level 4: Veneer Core & MDF
- Dowel (NEW)
Drawer Boxes
Duty Level 2: Particleboard
Duty Level 4: Hardwood
Duty Level 4: Particleboard
- Confirmat, 3/4" & 1/2"
- Confirmat with Applied Bottom, 3/4" & 1/2"
- Confirmat, 3/4"
- Confirmat with Applied Bottom, 3/4"
- Dowel, 3/4"
- Dowel with Applied Bottom, 3/4" & 1/2"
- Dowel with Applied Bottom, 3/4"
- Miterfold, 1/2"
- Miterfold, 3/4"
- Lockjoint, 1/2"
- Lockjoint, 3/4"
Duty Level 4: Veneer Core
- Confirmat, 3/4" & 1/2"
- Confirmat with Applied Bottom, 3/4" & 1/2"
- Confirmat, 3/4"
- Confirmat with Applied Bottom, 3/4"
- Dovetail, 1/2"
- Dovetail, 5/8"
- Dowel, 3/4" & 1/2"
- Dowel with Applied Bottom, 3/4" & 1/2"
- Dowel, 3/4"
- Dowel with Applied Bottom, 3/4"
- Lockjoint, 1/2"
- Lockjoint, 3/4"